Inspection method and inspection level of inspection items GB 2828-87 AQL GB 2828-87
See the corresponding product inspection standard documents for safety and pressure resistance requirements, without breakdown. II 0 Grounding resistance test: All metal parts directly connected to the grounding point are well grounded (12V 25A is not more than 0.1 Ω). II 0 35 lb. Power Lead Tension Test, after 1 minute, the power cord should not move more than 1/16†(1.6mm). S-1 0 Power Cord, Ballast Lead, Switch Lead, Socket Outlet and Other connecting wires must not have broken copper and copper, and the wiring of the power cord should be correct. The copper, the lamp holder and the starter socket should not be exposed. S-1 0 Insulation resistance is greater than 2M ohm, leakage current Not more than 10 mA. S-1 0 Barcode Scanning bar code with “Barcode Scannerâ€, the content of the bar code should be reliably detected. S-1 0 Electrical performance Electrical performance meets the requirements of the corresponding lamp product technical documents S-1 0.65 Starts normally, It can fully start in 3 seconds without flicker. S-1 0.65 Switch on and off must be smooth S-1 0.65 Wiring of assembly lamps should meet the requirements S-1 0.65 The matching dimensions of lampshade and adjacent components should meet the requirements S- 1 0.65 The components must be installed correctly and firmly. The installation dimensions should meet the requirements. The mutual cooperation should be good, and the screws should not be loose. S-1 0.65 The lamp installation direction is correct, and the lamp label must be visible on the front. S -1 0.65 The specifications, color and installation direction of the power cord must be correct. S-1 0.65 The specifications, color and exposed length of the power cord must meet the requirements of the technical documents. S-1 0.65 The contents of the kit must meet the requirements and be placed correctly. S-1 0.65 The appearance of the lamp housing, lampshade and other components should be correct. II 2.5 The appearance of the product is neat and tidy, and the parts such as brackets, lamps, lampshades, etc. must not show obvious dirt, spots, scratches, damage, etc. II 2.5 Lamps The outer casing shall not have obvious deformation, peaks, sharp corners, sharp edges, etc. S-1 2.5 Shell spraying shall be carried out in accordance with the “Guidelines for Painting Inspection Specifications.†--- --- No debris may appear in the packaging box or bracket. S-1 2.5 Packing boxes and labels shall not show obvious dirt, spots, scratches, breakage, etc. The printing code shall be clear and accurate, and the package shall not be peaked or scratched after being overmolded. S-1 2.5 Packaging Label Complete, clear content, correct location and orientation. S-1 2.5 Instructions should not be leaked or misplaced. S-1 2.5 The material, size, content and color of the package should meet the requirements. S-1 2.5
1

Anisotropic Cylinder Ferrite Magnets
Anisotropic Cylinder Ferrite Magnets,Disc Ferrite Magnet,Ferrite Ring Magnet,Ferrite Arc Magnet For Motor
HU NAN YUBANG MAGNETIC MATERIAL CO.,LTD , https://www.ybmagnet.com