Key parameters that must be paid attention to in the selection of pneumatic components

Pneumatic triplex generally refers to air filter, pressure reducing valve and oil mister. It is an important component in front of the control element after the gas path is in the air source. It filters the moisture of the gas impurity, decompresses it to the proper working pressure, and lubricates the entire oil mist. Gas line. Some brands of solenoid valves and cylinders are oil-free (lubricated by grease), eliminating the need for oil misters. Only air filters and pressure reducing valves can be combined as pneumatic two-pieces. It is also possible to assemble the air filter and the pressure reducing valve together to become a filter pressure reducing valve (the function is the same as that used in combination with the air filter and the pressure reducing valve). In some cases, oil mist may not be allowed in the compressed air, and an oil mist separator is required to filter out the oil mist in the compressed air. In short, these components can be selected according to the needs of the back-end equipment, and they can be combined and used.

Simply put, the selection of pneumatic components mainly depends on the following parameters:

1) Air flow rate: What is the total flow required for the following pneumatic components (such as solenoid valves, cylinders, etc.), and the overall size of the triplex is determined according to this flow rate.

2) Interface: What is the connection diameter (thread is a few minutes / a few inches ...)

3) Under the equipment factors and environmental conditions, what is required is manual drainage? Automatic drainage? Automatic drainage?

4) The air filter should be selected for filtration accuracy: the filtration accuracy refers to the maximum diameter of the particles passing through the filter element. Among them are 5μm, 10μm, 25μm, 50μm, etc., which can be selected according to the air quality requirements.

5) Select the triple piece according to the highest working pressure of the pneumatic control system. The source pressure should be 0.1 MPa greater than the maximum working pressure.

6) The pressure reducing valve should be selected according to the maximum operating pressure...

Of course, these are just some of the main parameters, and there are other technical parameters that may need further confirmation. When using a triple piece (pressure reducing valve), the lower limit of the pressure regulating range should be avoided as much as possible. It is best to use 30%-80% of the upper limit value, and should use a pressure gauge that meets this pressure regulation range. The pressure gauge reading should exceed 20% of the upper limit value.

When in use, the order in which the pneumatic components are generally installed is: The air flow direction is firstly the air filter, followed by the pressure reducing valve, and finally the oil mister. That is, according to the direction indicated by the arrow on the triple piece shell, the direction of the air flow cannot be reversed.

KNB1-32 Miniature Circuit Breaker

KNB1-32 Mini Circuit breakers, also named as the air switch which have a short for arc extinguishing device. It is a switch role, and also is a automatic protection of low-voltage electrical distribution. Its role is equivalent to the combination of switch. Fuse. Thermal Relay and other electrical components. It mainly used for short circuit and overload protection. Generally, According to the poles, mini Circuit breaker can be divided into 1P , 1P+N , 2P, 3P and 4P.


KNB1-32 Miniature Circuit Breaker,KNB1-32 Electronics Miniature Circuits Breaker,KNB1-32 Automatic Miniature Circuit Breaker,KNB1-32 Mini Circuit Breaker